Tutorials · User Manual

Point activation calculation

Confirm before you start

This example uses the .71c nuclear data library. After opening the supporting project, first check the materials, sources and tally parameters before starting the calculation.

The order of operations in this example
  1. Create point activation project
  2. Enter the total amount of material and energy spectrum
  3. Select output physical quantity
  4. Entry time plan item by item
  5. Run and check the curve

4.1 Point activation calculation

Generally speaking, the in-heap isotope density is a complex set of equations regarding the time variable t and the space variable. However, if the spatial distribution of nuclide density in a certain area is considered to be uniform and changes uniformly with time, and the neutron flux density in the area is assumed to be constant, then the area can be regarded as a point, thus ignoring the spatial variables in the system of equations and simplifying it to a system of equations about a single variable t, that is, a system of point activation equations. Therefore, point activation calculation requires setting the geometry and materials of the calculation model, and there is no need to set up transport calculation. Set up activation calculation directly. For details, see the 04-Point-Activation case in the included examples..\Examples folder. Point activation calculation has nothing to do with transport. The forward/reverse conversion function of MCNP calculation files is not supported yet. The subdirectory FISPACT under the example directory provides the input and output files of the third-party activation calculation program FISPACT for reference.

4.2 Point activation modeling

Enter the main interface of the program and select Action icon (Home>File>New Common), select point activation calculation in the pop-up New Calculation Model dialog box, and create a new point activation calculation model, as shown in the figure below.

Operation interface or graphics
Figure 1 New point activation model

Point activation material settings

Key settings

Click on the material on the left side of the program view to set it up, add a nuclide Fe56 with an atomic share of 1 and a mass density of 7.8 g/cc.

Operation interface or graphics
Figure 2 Activation material settings

Activation source settings

Click the source module in activation to enter the activation source setting interface. The total amount of activation material is set to the total volume 1 cm 3 (the total amount of activation material can be set to the total volume, total mass or total number of atoms as needed). Select GAM-II in the standard energy group structure, and the energy group structure of 100 groups will be automatically filled under the energy group boundary; enter the group flux under the energy spectrum (the number is one less than the energy group boundary. For the sake of uniform format, the first data is set to 0). In this example, enter the following values:

Full spectrum or energy group data (expand to copy)
0 4.99E+06 1.11E+07 8.45E+06 4.32E+06 6.71E+06 1.47E+07 1.69E+07 2.75E+061.51E+06 1.51E+06 5.33E+06 7.47E+06 2.29E+07 8.93E+06 1.10E+07 1.15E+07 7.67E+067.29E+06 6.63E+06 1.25E+07 8.87E+06 9.83E+06 9.03E+06 4.64E+06 1.16E+07 1.25E+071.65E+07 1.25E+07 9.80E+06 1.90E+07 2.03E+07 7.26E+06 1.04E+07 1.47E+07 1.31E+073.04E+07 1.06E+07 1.96E+07 2.35E+07 2.29E+07 6.85E+06 6.45E+06 8.69E+05 4.37E+061.47E+07 6.23E+06 5.85E+06 1.49E+07 1.73E+07 2.19E+07 2.36E+07 1.13E+07 1.51E+071.25E+07 1.69E+07 1.51E+07 1.12E+07 9.68E+06 9.57E+06 9.46E+06 4.25E+06 3.21E+065.01E+06 9.91E+06 2.77E+07 2.76E+07 2.11E+07 2.48E+07 2.09E+07 1.82E+07 1.50E+079.25E+06 1.96E+07 2.14E+07 1.49E+07 1.49E+07 1.85E+07 1.42E+07 1.40E+07 1.63E+071.24E+07 1.00E+07 9.87E+06 1.04E+07 9.52E+06 7.67E+06 7.38E+06 6.39E+06 5.59E+065.39E+06 3.86E+06 4.22E+06 2.84E+06 2.44E+06 1.96E+06 1.64E+06 1.60E+06 1.73E+062.67E+06 9.82E+05
Operation interface or graphics
Figure 3 Activation source settings

Activation tally settings

Key settings

Click the tally module in activation to enter the activation tally setting interface. The atom density can be cutoff, and the nuclide lower than the atom density cutoff will no longer be output. In this example, the atom density cutoff value is set to 1E5 (note that the setting is 1.0E-19, because the unit of the value entered here is 1E24). At the same time, you can check the physical quantities that need to be output in the output column below. Currently, the supported outputs include activity (Activity), atom density (Atoms), decay heat (Decay heat), contact dose (Contact dose), clearance index (Clearance index), decay gamma spectrum (Decay gamma spectrum), inhalation biohazard (ℎ) and potential biohazard (), nuclide contribution percentage (Contribution percent). Users can select the above activation feature quantities for calculation according to their needs.

Operation interface or graphics
Figure 4 Activation tally settings

Irradiation plan settings

Key settings

Set the irradiation scheme under the transport process module. The user can input the source intensity, which is set to 1 n/s in this example (because the total flux of the neutron energy spectrum used in this example is 1.12E9 n/(cm 2 ·s), the input total flux of the neutron energy spectrum is multiplied by the irradiation source intensity, and then multiplied by the source intensity factor factor below, which is equal to the Flux value set in FISPACT), select the neutron energy group structure of activation calculation For GAM-II, select fusion as the weight function type, and set the irradiation plan. The irradiation plan is set as follows: first irradiate for 1 day, 7 days, 1 month, and 1 year, with a source intensity factor of 1; then cool for 1 day and 1 month.

Operation interface or graphics
Figure 5 Irradiation plan settings

4.3 Calculation

After completing the above settings, click the "simple calculation" button Action icon, select the folder where the calculation results are saved, and you can perform point activation calculation.

4.4 Results visualization

After the calculation is completed, click the "Visual Interface" button Action icon Open the results visualization interface, and the calculation results will be automatically imported into the interface. In this example, the correlation curves of the activation attribute and decay gamma spectrum can be drawn separately.

Select the "Acti-(point)" node, and select the display status (active) in the edit page tab of the "data management panel"

Characterization quantity) check box, and then click the eye icon next to the node, you can draw the activity curve of the relevant material obtained by point activation calculation. Similar to this, you can also get the change curves of other physical quantities by selecting the other check boxes.

Picture and text on page 108 of the manual
Figure 6 Drawing of activation attribute curve

Select the "Acti-(point)" node, select "decay gamma spectrum" from the

Picture and text on page 108 of the manual
Figure 7 Activation attribute curve drawing

What to check in the results

Result check

Check the activity and decay gamma spectrum at each irradiation/cooling time point. The total neutron flux in the example is 1.12E9 n/(cm²·s). The actual normalization must be combined with the input energy spectrum, irradiation source intensity and factor.

Important note

No transport calculation setting is required, and MCNP forward and reverse conversion is not supported yet. The FISPACT subdirectory provides third-party input and output for comparison; see the complete energy spectrum below to copy the text.

Show the full parameter text (copyable)
【Parameter information 104】
104

3.4 Point activation calculation

In general, the in-heap isotope density is a complex set of equations with respect to the time variable t and the space variable. However if

If it is considered that the spatial distribution of nuclide density in a certain area is uniform and changes uniformly with time, it is also assumed that the area

If the neutron flux density in the domain is constant, the region can be regarded as a point, thus ignoring the spatial variables in the system of equations,

Simplified to a system of equations about a single variable t, the point activation system of equations. Therefore, point activation calculation needs to set the calculation mode

For the geometry and materials of the model, there is no need to set the transport calculation and set the activation calculation directly. See the included example for details

04-Point-Activation case under the title..\Examples folder. point activation calculation has nothing to do with transport and is not supported yet.

MCNP calculation file forward/inverse conversion function. The subdirectory FISPACT under the example directory provides a third-party activation plan.

The input and output files of the calculation program FISPACT are provided for reference.

3.4.1 Point activation modeling

Enter the main interface of the program, select (Home>File>New Common), and create a new calculation model pair in the pop-up

Select point activation calculation in the dialog box and create a new point activation calculation model, as shown in the figure below.

Figure 3.4.1 New point activation model

Point activation material settings

Click Materials on the left side of the program view to set up a nuclide Fe56 with an atomic share of 1 and a mass density of

The degree is 7.8 g/cc, as shown in the figure below.
【Parameter information 105】
105

Figure 3.4.2 Activation material settings

Activation source settings

Click the source module in activation to enter the activation source setting interface. The total amount of activation material is set to a total volume of 1 cm3

(The total amount of activation material can be set to total volume, total mass, or total number of atoms as needed). Standard energy group knot

Select GAM-II in the structure, and the energy group structure of 100 groups will be automatically filled in under the energy group boundary; enter the group structure under the energy spectrum.

Amount (the number is one less than the energy group boundary. For the sake of uniform format, the first data is set to 0). In this example, enter the following value:

0 4.99E+06 1.11E+07 8.45E+06 4.32E+06 6.71E+06 1.47E+07 1.69E+07 2.75E+06

1.51E+06 1.51E+06 5.33E+06 7.47E+06 2.29E+07 8.93E+06 1.10E+07 1.15E+07 7.67E+06

7.29E+06 6.63E+06 1.25E+07 8.87E+06 9.83E+06 9.03E+06 4.64E+06 1.16E+07 1.25E+07

1.65E+07 1.25E+07 9.80E+06 1.90E+07 2.03E+07 7.26E+06 1.04E+07 1.47E+07 1.31E+07

3.04E+07 1.06E+07 1.96E+07 2.35E+07 2.29E+07 6.85E+06 6.45E+06 8.69E+05 4.37E+06

1.47E+07 6.23E+06 5.85E+06 1.49E+07 1.73E+07 2.19E+07 2.36E+07 1.13E+07 1.51E+07

1.25E+07 1.69E+07 1.51E+07 1.12E+07 9.68E+06 9.57E+06 9.46E+06 4.25E+06 3.21E+06

5.01E+06 9.91E+06 2.77E+07 2.76E+07 2.11E+07 2.48E+07 2.09E+07 1.82E+07 1.50E+07

9.25E+06 1.96E+07 2.14E+07 1.49E+07 1.49E+07 1.85E+07 1.42E+07 1.40E+07 1.63E+07

1.24E+07 1.00E+07 9.87E+06 1.04E+07 9.52E+06 7.67E+06 7.38E+06 6.39E+06 5.59E+06

5.39E+06 3.86E+06 4.22E+06 2.84E+06 2.44E+06 1.96E+06 1.64E+06 1.60E+06 1.73E+06

2.67E+06 9.82E+05
【Parameter information 106】
106

Figure 3.4.3 Activation source settings

Activation tally settings

Click the tally module in activation to enter the activation tally setting interface. Atom density can be cutoff, below

The nuclide of atom density cutoff nucleon cutoff will no longer be output. In this example, the atom density cutoff value is set to 1E5 (note that the

The setting is 1.0E-19 because the value entered here is in units of 1E24). At the same time, you can check the required

The output physical quantities currently support the output of activity (Activity), atom density (Atoms), decay heat (Decay

heat), contact dose (Contact dose), clearance index (Clearance index), decay gamma spectrum (Decay

gamma spectrum), inhalation biohazard (𝐵𝐻ℎ) and potential biohazard (𝐵𝐻𝑃), nuclide tribute

Contribution percent. Users can select the above activation feature quantities for calculation according to their needs.

Figure 3.4.4 Activation tally settings
【Parameter information 107】
107

Irradiation plan settings

Set up the irradiation scheme under the transport process module. The user can enter the source strength, which is set to 1 n/s in this example (because

The total flux of the neutron energy spectrum used in this example is 1.12E9 n/(cm2·s). The input total flux of the neutron energy spectrum is multiplied by the irradiation

Source strength, then multiplied by the source strength factor factor below, which is equal to the Flux value set in FISPACT), select the activation calculation

The calculated neutron energy group structure is GAM-II, the weight function type is selected as fusion, and the irradiation scheme is set.

The irradiation plan is set as follows: first irradiate for 1 day, 7 days, 1 month, and 1 year, with the source intensity factor being 1; then cool for 1 day and 1 month.

Figure 3.4.5 Irradiation plan settings

3.4.2 Calculation

After completing the above settings, click the "simple calculation" button and select the folder to save the calculation results.

Line point activation calculation.

3.4.3 Results visualization

After the calculation is completed, click the "Visualization Interface" button to open the result visualization interface, and the calculation results will automatically

Import into this interface. In this example, the correlation curves of the activation attribute and decay gamma spectrum can be drawn separately.

Select the "Acti-(point)" node, and select the display status (active) in the edit page tab of the "data management panel"
【Parameter information 108】
108

(Feature quantity) checkbox, and then click the eye icon next to the node to draw the relevant material obtained by point activation calculation.

The activity curve of the material is shown in the figure below. Similar to this, you can also get changes in other physical quantities by selecting the remaining check boxes.

Curve.

Figure 3.4.6 Drawing of activation attribute curve

Select the "Acti-(point)" node and select it from the X drop-down list in the edit page tab of the "data management panel"

"decay gamma spectrum", then select a time point in the list below, click the eye icon next to the node, and draw

The change curve of the decay gamma spectrum is shown in the figure below.

Figure 3.4.7 Drawing of activation attribute curve